RSF 84E (T) 100E (T) Technical Details small logo

FURTHER HIGH EFFICIENCY BOILERS
LS80/100 (T)
RSF82/820/20 (T)

RSF84/100
RSF84/100 (T)


RSF84E (T) 100 E(T)

High Performance

High Flow Rate

7 Day Digital Timer As Standard

Energy Saving Ignition System

Multi Level Safety Features

User Variable Thermostats

Fully Modulating

 


 

"With many years of experience and innovative designs, Ravenheat have proved convincingly that central heating needn't cost the earth."

 

 

Net Efficiencies
CENTRAL HEATING   MODEL RSF84E (T) MODEL RSF100E (T)
OUTPUT MAX-MIN kW 24.6 - 11.5 29.66 - 11.2
ADJUSTABLE Btu/oh 83,900 - 39,250 101.220 - 38,220
DOMESTIC HOT WATER      
FLOW RATE RAISED 30°C At I/min 10.1 (2.60 gals/min) 14.2 (3.12 gals/min)
  35°C At I/min 10.1 (2.22 gals/min) 12.2 (2.68 gals/min)
DOMESTIC HOT WATER      
OUTPUT kW 24.6 - 11.5 29.66 - 11.22
MAX - MIN Btu/oh 83,900 - 39,250 101.220 - 38.220
EXPANSION VESSEL I 8 8
MAX CENTRAL HEATING TEMPERATURE °C 85° 85°
CONNECTION      
HEATING FLOW & RETURN COMPRESSION mm 22 22
GAS CONNECTION mm 15 15
DOMESTIC SUPPLY (COLD).COMPRESSION mm 15 15
DOMESTIC SUPPLY (HOT) COPPER mm 15 15
       
WEIGHT Kg 46 49
FLUE SIZE mm 100 100
ELECTRICAL MAINS SUPPLY     230v 50hZ
SEDBUK NAT GAS % 78.8 BAND D 78.9 BAND D
  LPG % 81.0 BAND D 81.2 BAND D

 


Flue Options

Concentric Flue Duct.
The boiler comes complete with a standard horizontal flue kit (1 metre long). If required the flue may be extended up to 2.5 metres horizontally. A vertical flue is also available where a horizontal flue is not possible or desired and can run up to 4 metres vertically in length, by the use of flue extension pipes.

Eccentric Flue Duct.
This boiler can be used with the eccentric flue system - enabling flueing up to 29 metres air intake/exhaust from the boiler. A special two way header can be fitted to the top of the appliance which guarantees a perfect connection between the boilers sealed combustion chamber and the two pipes.

CONCENTRIC ECCENTRIC
1 VERTICAL FLUE TERMINAL
2 90° BOILER FLUE BEND
3 BOILER STRAIGHT FLUE HEADER
4 FLUE EXTENSION (1000mm)
5 EXTERNAL FLUE COLLAR
6 HORIZONTAL FLUE TERMINAL
7 90° IN LINE BEND
8 45° IN LINE BEND
9 FLASHING SLEEVE
9 FLASHING SLEEVE
10 90° BEND FOR USE WITH INTAKE AND EXHAUST
11 HORIZONTAL AIR INLET TERMINAL
12 HORIZONTAL FLUE EXHAUST TERMINAL
13 45° BEND FOR USE WITH INTAKE AND EXHAUST
14 FLUE EXTENSION (1000mm) FOR USE WITH INTAKE AND EXHAUST
15 TWIN FLUE STRAIGHT HEADER
16 VERTICAL TWIN FLUE TERMINAL

 


Component List

1 air pressure switch
2 sealed combustion
3 heat exchanger
4 safety thermostat
5 DHW heat exchanger
6 spark electrode
7 modulating gas valve
8 low water cut-off switch
9 DHW thermostat control
10 isolating valve
11 central heating thermostat
12 isolating valve
13 isolating valve
14 safety valve
15 water gauge/thermostat
16 circulation pump
17 shunt valve
18 DHW priority pressure switch
19 burner
20 expansion vessel
21 cut-off thermostat
22 fan
23 automatic air vent
24 concentric bend fitting
25 straight cocentric fitting
26 two-way flue gas header
(for eccentric exhaust connection)

 

Beautifully designed and engineered Ravenheat are working for a cleaner, greener future
Ravenheat - The Caring Company