Net
Efficiencies
| |
MODEL
- HE PRIMARYAAA (T) |
INPUT
MAX-MIN NETT
ADJUSTABLE |
kW |
24.8
- 13.0 |
| Btu/h |
84.500
- 44.500 |
| |
|
|
OUTPUT
MAX-MIN
ADJUSTABLE |
kW |
25.6
- 13.4 |
| Btu/h |
87.200
- 45.700 |
| MAXIMUM
NETT EFFICIENCY |
|
103.1/96.8% |
| |
|
|
| MAX
CENTRAL HEATING TEMPERATURE |
°C |
85º |
| |
|
|
| CONNECTION |
|
|
HEATING
FLOW & RETURN COPPER
GAS CONNECTION |
mm |
22 |
| CONDENSING
PIPE 3/4 PUSH FIT OVERFLOW PIPE |
mm |
15 |
| |
|
|
| WEIGHT |
Kg |
42 |
| FLUE
SIZE |
mm |
100 |
|
|
|
| ELECTRICAL
MAINS SUPPLY |
|
240v
50 hz FUSED 3 amp |
| SEDBUK |
NAT
GAS |
% |
90.2
BAND A |
| |
LPG |
% |
92.2
BAND A |
Models
HE PrimaryAAA (T)100mm Concentric Flue System
| PART |
DESCRIPTION |
BARCODE |
RAVENHEAT
PART NO. |
| 1
+ 3 |
Vertical
Flue terminal kit
+ straight flue header |
5060022141995
+ 5060022141186 |
N5094130
+ 5094110B |
| 2 |
90
deg boiler bend |
5060022141209 |
CSIFB |
| 3 |
Straight
flue header |
5060022141186 |
5094110B |
| 4 |
1000mm
flue extension |
5060022141339 |
NFE |
| 5 |
External
flue collar |
|
Supplied
with No.6 |
| 6 |
Horizontal
flue kit complete with boiler bend |
5060022141230 |
CSIFKB |
| 7 |
45
deg in line bend |
5060022141247 |
N45FBI |
| 7 |
90
deg in line bend |
5060022141315 |
N90FBI |
| 9 |
Vertical
lead flashing sleeve - pitched roof |
5060022141063 |
0019TEG06005/0 |
| 10 |
Plume
kit |
5060022143142 |
1019TER11010/0 |
The
above flue arrangements should fit most requirements however,
alternative systems (twin or 125mm) are available for longer flue
distances.
Flue
Options
The
HE PrimaryAAA (T) can be fitted with a standard
(concentric) flue duct or a twin (eccentric) flue duct, which
can be installed either vertical or horizontal, depending on the
customers requirements.
Normally
supplied with a 1 metre standard flue kit, it can be extended
to 2.5 metres if required. Eccentric flue ducting is ideal for
covering long distances and with a special Ravenheat connector
can be extended up to 23 metres air intake/exhaust.

Operating
Scheme

1
Heat exchanger
3 Burner
5 Flue restriction ring
6 Condensing heat exchanger
7 Electronic ignition
8 Condensing trap
9 Ignition electrode
12 Gas valve |
15
Heating output control
18 Overheat cut-off thermostat
20 Gas service cock
22 Condensate sump
26 Auto air vent valve
28 Air pressure switch
36 Fan
38 Sealed chamber |
Condensation
drain |
Heating
supply system |
Gas
Input |
Heating
system return |
Overall Dimensions