Net
Efficiencies
| CENTRAL
HEATING |
MODEL
HE 85 AAA (T) |
| INPUT
MAX-MIN NETT |
kW |
23.9
- 11.4 |
OUTPUT
MAX-MIN NETT
ADJUSTABLE |
kW |
23.9
- 11.4 |
| DOMESTIC
HOT WATER |
|
|
| INPUT
MAX - MIN |
kW |
26.0
- 13.4 |
| OUTPUT
MAX - MIN |
kW |
25.6
- 13.0 |
| |
|
|
| DOMESTIC
HOT WATER |
|
|
| FLOW
RATE RAISED |
30°C
At |
I/min |
12.8
(2.81 gals/min) |
| 6°
INLET TEMP |
35°C
At |
I/min |
11.0
(2.42 gals/min |
| EXPANSION
VESSEL |
I |
8/1 |
| MAX
CENTRAL HEATING TEMPERATURE |
°C |
90° |
| |
|
|
| CONNECTION |
|
|
| HEATING
FLOW & RETURN COMPRESSION |
mm |
22 |
| GAS
CONNECTION |
|
1/2
BSP |
| DOMESTIC
SUPPLY (COLD).COMPRESSION |
mm |
15 |
| DOMESTIC
SUPPLY (HOT) COPPER |
mm |
15 |
| CONDENSING
PIPE 3/4 PUSH FIT OVERFLOW PIPE |
|
|
| FLUE
SIZE |
mm |
100 |
| ELECTRICAL
MAINS SUPPLY |
|
240v
50 hz FUSED 3 amp |
| SEDBUK |
NAT
GAS |
% |
90.1
BAND A |
| |
LPG |
% |
92.6
BAND A |
Flue Options
Model
HE 85AAA (T) 100mm Concentric Flue System
| PART |
DESCRIPTION |
BARCODE |
RAVENHEAT
PART NO. |
| 1
+ 3 |
Vertical
Flue terminal kit
+ straight flue header |
5060022141995
+ 5060022141186 |
N5094130
+ 5094110B |
| 2 |
90
deg boiler bend |
5060022141209 |
CSIFB |
| 3 |
Straight
flue header |
5060022141186 |
5094110B |
| 4 |
1000mm
flue extension |
5060022141339 |
NFE |
| 5 |
External
flue collar |
|
Supplied
with No.6 |
| 6 |
Horizontal
flue kit complete with boiler bend |
5060022141230 |
CSIFKB |
| 7 |
45
deg in line bend |
5060022141247 |
N45FBI |
| 7 |
90
deg in line bend |
5060022141315 |
N90FBI |
| 9 |
Vertical
lead flashing sleeve - pitched roof |
5060022141063 |
0019TEG06005/0 |
| 10 |
Plume
kit |
5060022143142 |
1019TER11010/0 |
The
above flue arrangements should fit most requirements however, alternative
systems (twin or 125mm) are available for longer flue distances.
The HE 85 AAA (T) can be fitted
with a standard (concentric) flue duct or a twin (eccentric) flue
duct, which can be installed either vertical or horizontal, depending
on the customers requirements.
Normally
supplied with a 1 metre standard flue kit, it can be extended to 2.5
metres if required. Eccentric flue ducting is ideal for covering long
distances and with a special Ravenheat connector can be extended up
to 23 metres air intake/exhaust.

Operating
Scheme

1
Heat exchanger
2 Heat exchanger for tap water
3 Burner
5 Flue restriction ring
6 Condensing heat exchanger
7 Electronic ignition
8 Condensing trap
9 Ignition electrode
12 Modulating gas valve
15 Heating control potentiometer
thermostat
16 Hot water control potentiometer
thermostat
17 Water pressure switch
18 Overheat cut-off thermostat |
20
Gas service cock
21 Compression ball valve
22 Condensate sump
23 Safety release system
24 Three way valve
25 Flow regulator
26 Auto air vent valve
27 Pressure switch giving
priority DHW
28 Air pressure switch
29 Circulating pump
30 Water pressure gauge
36 Fan
37 Expansion tank
38 Sealed chamber |
Overall
Dimensions

| |
A |
B |
C |
D |
E |
| HE
85A (T) |
422 |
450 |
850 |
360 |
200 |