CSI85b (T) Technical Details small logo

FURTHER HIGH EFFICIENCY BOILERS
LS80/100 (T)
RSF82/820/20 (T)

RSF84/100
RSF84/100 (T)


CSI 85b (T)

Save 35% On Your Heating Bill

96% Efficient

Winner of the International Award of Excellence

5 Year Heat Exchanger Warranty

Reduced greenhouse emissions

East Installation and Simple To Operate

 


 

"With many years of experience and innovative designs, Ravenheat have proved convincingly that central heating needn't cost the earth."

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Efficiencies

CENTRAL HEATING MODEL CSI 85b (T)
INPUT MAX-MIN NETT kW 23.9 - 11.4
OUTPUT MAX-MIN NETT
ADJUSTABLE
kW 23.9 - 11.4
DOMESTIC HOT WATER    
INPUT MAX - MIN kW 26.0 - 13.4
OUTPUT MAX - MIN kW 25.6 - 13.0
     
DOMESTIC HOT WATER    
FLOW RATE RAISED 30°C At I/min 12.8 (2.81 gals/min)
6° INLET TEMP 35°C At I/min 11.0 (2.42 gals/min
EXPANSION VESSEL I 8/1
MAX CENTRAL HEATING TEMPERATURE °C 90°
     
CONNECTION    
HEATING FLOW & RETURN COMPRESSION mm 22
GAS CONNECTION   1/2 BSP
DOMESTIC SUPPLY (COLD).COMPRESSION mm 15
DOMESTIC SUPPLY (HOT) COPPER mm 15
CONDENSING PIPE 3/4 PUSH FIT OVERFLOW PIPE    
FLUE SIZE mm 100
ELECTRICAL MAINS SUPPLY   240v 50 hz FUSED 3 amp
SEDBUK NAT GAS % 88.0 BAND B
  LPG % 90.0 BAND A

 


Flue Options

The new CSI 85b can be fitted with either a 100mm standard (concentric), a 125mm flue duct or a twin (eccentric) flue duct, which can be installed either vertical or horizontal, depending on the customer's requirements.
Normally supplied with a 1 metre standard horizontal flue kit, this can be extended to 2.5 metres if required, or 3.5 metres vertical (maximum without bends).

Alternatively there is a 125mm (concentric) flue system that allows greater flexibility. Eccentric flue ducting is ideal for covering long distances and when used with a special Ravenheat connector this can be extended up to 12 metres air intake/exhaust.

 

1 vertical concentric flue gas exhaust duct
2 concentric elbow bend
3 straight concentric connection
4 concentric extension
5 fastening ring
6 horizontal concentric flue exhaust duct
7 concentric inline bend
10 air intake bend 90°
10 flue exhaust bend 90°
11 air inlet terminal
12 flue exhaust terminal
13 45° air intake bend
13 45° flue exhaust bend
14 flue exhaust duct
14 air intake duct
15 two-way flue gas header
16 vertical eccentric flue
exhaust duct

 


Operating Scheme

 

1 Heat exchanger
2 Heat exchanger for tap water
3 Burner
5 Flue restriction ring
6 Condensing heat exchanger
7 Electronic ignition
8 Condensing trap
9 Ignition electrode
12 Modulating gas valve
15 Heating control potentiometer
thermostat
16 Hot water control potentiometer
thermostat
17 Water pressure switch
18 Overheat cut-off thermostat
20 Gas service cock
21 Compression ball valve
22 Condensate sump
23 Safety release system
24 Three way valve
25 Flow regulator
26 Auto air vent valve
27 Pressure switch giving
priority DHW
28 Air pressure switch
29 Circulating pump
30 Water pressure gauge
36 Fan
37 Expansion tank
38 Sealed chamber


Overall Dimensions

 

  A B C D E
CSI 85b (T) 422 450 850 360 200

Technical after-sales service
Ravenheat is proud of its track record in producing extremely reliable boilers and its service response and commitment is immediate. Ravenheat only uses its own highly qualified technicians thereby ensuring the highest quality, and most reliable customer care.


In the unlikely event of an application failure, Ravenheat has a technical helpline at its central headquarters in Leeds.

Service engineers or their customers telephoning this line have the satisfaction of knowing they will receive advice and the knowledge that one of Ravenheat's own technicians is on hand should an on site visit be required.



Ravenheat also run their own unique comprehensive installer training programme working alongside the regulative bodies and trade associations. This all adds up to Ravenheat's uncompromising commitment to product quality, efficiency and service.

Quality Assurance
Ravenheat not only operate a quality ISO9002 system. Indeed we hold the highest accolade in design manufacturing excellence, being one of the few manufacturers to hold ISO9001:2001system, for quality of design, something very few boiler manufacturers can achieve. This quality system ensures you the customer, of Ravenheat's commitment to excellence right across the product range. Each boiler is fully factory tested for fifteen minutes, to ensure it arrives on site 100% function tested.
Beautifully designed and engineered Ravenheat are working for a cleaner, greener future
Ravenheat - The Caring Company
Contact Us
©2006 Ravenheat Manufacturing Ltd +44 (0)113 252 7007